MODEL HDR (BB2)
  Single Stage Double Suction Pumps
Fully compliant with API 610 requirements
  Operating Parameters:
• Flow rate in excess of 25,000 USGPM (5,700 m3/h).
• Differential heads up to 1,400 FT (425 m).
• Temperatures up to 800 Deg. F (425 Deg. C).
• Standard Design Working Pressure of 725 PSIG (5,000 kpag).
• Higher pressure designs available.
  Standard Features:
• Widest hydraulic coverage in the industry.
• Application tailored hydraulic selections.
• 300# flange ratings, with side suction or top suction
    design casings.
  • Available in all API 610 Table H-1 materials.
• Cast or fabricated impellers, for expanded hydraulic coverage.
• Close clearance metalized carbon throat bushing for optimal
    control of stuffing box environment.
  • Rigid design shaft for minimal deflection to meet and exceed
    API 610 requirements.
  • Cylindrical roller radial bearings for ample load carrying capability.
  • Duplex angular contact 7300 series thrust bearings.
• Inpro/Seal bearing housing isolators.
• Heavy Duty baseplate, drip rim or drip pan designs.
  Optional Features:
• High pressure special casing design.
• Oversized shafts and bearing housing arrangements.
• Fan/Heat-sink bearing housing cooling arrangement for operation
    at elevated temperatures, to eliminate the need for cooling water.
  • Magnetic bearing housing isolators.
• All bearing combination arrangements are available where
    suitable: Ball/Ball, Sleeve/Ball, Tilt Pad/Sleeve.

 
  Model: HDR-BB2
  Type: Between Bearing, Double Suction
  Max Capacity: USGPM 25,000
M#/Hr 5,700
  Max Head: Feet 1,400
  M 425
  Max Temperature: F 800
  C 425
  Std. Pressure: PSIG 725
  Kpa 5,000
  Opt. Pressure: PSIG 3,750
  Kpa 26,000
   
   
   
Typical Application:
Double suction, centre-line mounted pumps
designed for high temperatures and pressures withtop/top nozzles.