MODEL H2R (BB2)
  Two Stage Single or Double Suction First Stage
Pumps Fully compliant with API 610 requirements
  Operating Parameters:
• Flow rate in excess of 6,200 USGPM (1,400 m3/h).
• Differential heads up to 2,800 FT (850 m).
• Temperatures up to 800 Deg. F (425 Deg. C).
• Standard Design Working Pressure of 725 PSIG (5,000 kpag).
• Higher pressure designs available.
  Standard Features:
• Widest hydraulic coverage in the industry.
• Application tailored hydraulic selections.
• 600/900/1500# flange ratings.
• Controlled compression fully confined gasket fit, case to cover.
• Available in all API 610 Table H-1 materials.
• Close clearance metalized carbon throat bushing for optimal
    control of stuffing box environment.
• Rigid design shaft for minimal deflection to meet and exceed
  API 610 requirements
• Inpro/Seal bearing housing closures.
• Rigid cast Carbon steel bearing housings, with fins for
    improved heat dissipation.
  • Heavy duty baseplate, drip rim or drip pan designs.
  Optional Features:
• High pressure special casing designs.
• Fan/Heat-sink bearing housing cooling arrangement for operation
    at elevated temperatures, to eliminate the need for cooling water
• Magnetic bearing housing isolators.
• All bearing combination arrangements are available where
  suitable: Ball/Ball, Sleeve/Ball, Tilt Pad/Sleeve


 
  Model: H2R-BB2
  Type: Between Bearing
  Max Capacity: USGPM 6,200
M#/Hr 1,400
  Max Head: Feet 2,800
  M 850
  Max Temperature: °F 800
  °C 425
  Std. Pressure: PSIG 725
  Kpa 5,000
  Opt. Pressure: PSIG 3,750
  Kpa 26,000
   
   
   
Typical Application:
Two stage, center-line mounted pumps designed
for high temperature services requiring differential
head beyond the capabilities of single stage
pumps.