Testing
 
To ensure that CPC pumps meet our customer’s
specifications and expectations, each unit must
successfully pass the following tests:
 
• Hydrostatic pressure
• Hydraulic performance
• Vibration
• Mechanical reliability
• Air test of complete assembled unit prior to shipment
 
Testing Capabilities
 
• 30,000 gallon (114 m3) test tank
• Up to 4500hp (3350kW) VFD Drive
• Test motor voltages of 460V, 575V, 6kV, 10kV, 11kV,
  13kV and 13.6kV
• Hydrostatic testing up to 8000 PSIG (55200 kpag)
• MPI, LP and RT non-destructive examination available
• Hardness testing
• PMI on alloys
 
Custom testing catered to customer and job