Testing
CPC Pumps hydraulic pump performance
stand can test pump units up to 1200 HP at 1800 or 1200 RPM
- Customers motors can be used (if large enough @ 1.0 SGR) at
voltages of 450, 575, 2300, and 4160 at 3 Ph, 60Hz
- Variable frequency drives are available to 150 HP
- Hydrostatic testing can be performed using water or kerosene,
up to 8000 PSIG
To insure that CPC Pumps meet our customers specifications and expectations,
each unit must successfully pass the following tests:
- Hydro static pressure
- Hydraulic performance
- Vibration
- Noise
- Mechanical reliability
- Air test of complete assembled unit prior to shipment
Quality CPC Pumps quality program has been approved
by:
- Canadas NPM Nuclear Project for the manufacturing
of nuclear centrifugal pumps.
- Canadas Standard Association to manufacture pumps using
CSA Z299.2 or CSA Z299.3, quality program standards.
- Ontarios Pressure Vessel Safety Branch to manufacture
centrifugal pumps in accordance with the ASME boiler and pressure
vessel code, section III, division I, class 3.
As an additional commitment to quality, each CPC
pump is inspected prior to shipment by an engineering representative
to confirm the completed assembly meets customer specifications
concerning:
- Flush and cooling piping
- Outline drawing dimensions
- Name plate data
- Tagging of connection
- Overall appearance
|